Stem Mounting Photocells
- 1w 120vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,2000 Watt;ballast Load Rating,1800 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,180 Deg Swivel;enclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2001Customer Part#Campbell Part# TOR2001
- 1w 120vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,2000 Watt;ballast Load Rating,1800 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,fixedenclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2000Customer Part#Campbell Part# TOR2000
- 1w 120vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,2000 Watt;ballast Load Rating,1800 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,180 Deg Swivel Pencil;enclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2021Customer Part#Campbell Part# TOR2021
- 1w 208 To 277vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,3470 To 4620 Watt;ballast Load Rating,2080 To 2770 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,180 Deg Swivel;enclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2002Customer Part#Campbell Part# TOR2002
- 1w 208 To 277vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,3470 To 4620 Watt;ballast Load Rating,2080 To 2770 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,fixedenclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2000-2Customer Part#Campbell Part# TOR2000-2
- 1w 120vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,3000 Watt;ballast Load Rating,3000 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt Stem;mounting Position,fixedenclosure Material,polycarbonate;size,1 9/16" W X 1 9/16" D X 3" HDetailed Description LessBrandIntermaticMfr. Part#K4141CCustomer Part#Campbell Part# INTK4141C
- 1w 208 To 277vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,3100 To 4150 Watt;ballast Load Rating,1700 To 2300 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt Stem;mounting Position,fixedenclosure Material,polycarbonate;size,1 9/16" W X 1 9/16" D X 3" Happroval,ul, Csa (canada And Us)Detailed Description LessBrandIntermaticMfr. Part#K4123CCustomer Part#Campbell Part# INTK4123C
- 2w 120vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,1800 Watt;ballast Load Rating,1000 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt;mounting Position,swivel;enclosure Material,polycarbonate;size,1 9/16" W X 1 9/16" D X 5 1/2" Happroval,ul, Csa (canada And Us)Detailed Description LessBrandIntermaticMfr. Part#K4221CCustomer Part#Campbell Part# INTK4221C
- 1w 208 To 277vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,3470 To 4620 Watt;ballast Load Rating,2080 To 2770 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";mounting Position,180 Deg Swivel Pencil;enclosure Material,lexan;application,flood Lamp, Patio Lamp, Decorative Lighting;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2022Customer Part#Campbell Part# TOR2022
- 1w 120vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,1800 Watt;ballast Load Rating,1000 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt Stem;mounting Position,fixedenclosure Material,polycarbonate;size,1 9/16" W X 1 9/16" D X 3" Happroval,ul, Csa (canada And Us)Detailed Description LessBrandIntermaticMfr. Part#K4121CCustomer Part#Campbell Part# INTK4121C
- 2w 120vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,1800 Watt;ballast Load Rating,1000 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt;mounting Position,swivel;enclosure Material,polycarbonate;size,1 3/8" Dia X 4" Happlication,spot/flood Light Fixtures;approval,csa (canada And Us)Detailed Description LessBrandIntermaticMfr. Part#K4251Customer Part#Campbell Part# INTK4251
- 1w 120vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,2000 Watt;ballast Load Rating,1800 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";enclosure Material,die Cast Zinc;application,parking Lot Lighting, Building Perimeter Lighting, Outdoor Signage;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2129ACustomer Part#Campbell Part# TOR2129A
- 1w 208 To 277vac Relay Stem Mounting PhotocontrolType,relay;tungsten Load Rating,3470 To 4620 Watt;ballast Load Rating,2080 To 2770 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,16 Awg 6" Wire Leadtemperature Rating, 40 To 140 Deg F;mounting,1/2";enclosure Material,die Cast Aluminum;application,parking Lot Lighting, Building Perimeter Lighting, Outdoor Signage;approval,ul (canada And Us)Detailed Description LessBrandNSIMfr. Part#2116Customer Part#Campbell Part# TOR2116
- 2w 208 To 277vac Thermal Stem Mounting PhotocontrolType,thermal;tungsten Load Rating,3100 To 4150 Watt;ballast Load Rating,1700 To 2300 Volt Amp;turn On Light Level,1 To 5 Fc;turn Off Light Level,turn Off Light Level;terminal Type,6" Leadtemperature Rating, 40 To 158 Deg F;mounting,1/2" 14 Npt;mounting Position,swivel;enclosure Material,polycarbonate;size,1 9/16" W X 1 9/16" D X 5 1/2" Happroval,csa (canada And Us)Detailed Description LessBrandIntermaticMfr. Part#K4223CCustomer Part#Campbell Part# INTK4223C
- Photocontrol 1/2 Inch Conduit Stem Mount 600VA LED 120/208-277 Volt 2000 Watt Tungsten 1800VA Ballast Die Cast AluminumBrandNSIMfr. Part#2119ACustomer Part#Campbell Part# TOR2119A