Dry-Well Calibrators
- Industrial Dual-block Thermometer Dry-well Calibrator With Two 1/4" And Two 3/16" Inserts, Black Case, 110v, 50/60hzFluke Calibration Industrial Dual-block Thermometer Dry-well Calibrator With Two 1/4 And Two 3/16 Inserts, Black Case, 110v, 50/60hz.Detailed Description LessBrandFlukeMfr. Part#9009-B-156Customer Part#Campbell Part# FLU9009-B-156
- HDRC Handheld Dry-Well Hi-Temperature Calibrator, Block A, 35 to 375C Temperature Range, 115VSince we introduced the worlds first truly handheld dry-well, many have tried to duplicate itin vain. Despite its small size (2 inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world. Its simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375C (707F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.Detailed Description LessBrandFlukeMfr. Part#9100S-A-156Customer Part#Campbell Part# FLU9100S-A-156
- HDRC Handheld Dry-Well Hi-Temperature Calibrator, Block A, 35 to 375C Temperature Range, 115VThis Dry-well Is Only Four Inches High And Six Inches Wide, Reaches Temperatures As Low As 10degrees Celsius, Includes A Nist-traceable Calibration, And Is Stable To Plus Or Minus0.05degrees Celsius. The Model 9102s Is Excellent For Dial Gauges, Digital Thermometers, Bulb Switches, And Other Sensors That Need Calibration Below Ambient. It Has Two Wells So You Can Use One For A Reference Thermometer To Increase Accuracy. Both Wells Are 1/2 Inch In Diameter, And Each Has Inserts Available For Almost Any Sensor Size. It Also Has A Battery Pack Option That Gives You Approximately Four Hours Of Field Use When Ac Power Is Unavailable. Block b Has Four Holes That Accept Probe Diameters Of 3/8, 1/4, 3/16 And 1/8.Detailed Description LessBrandFlukeMfr. Part#9100S-B-156Customer Part#Campbell Part# FLU9100S-B-156
- HDRC Handheld Dry-Well Hi-Temperature Calibrator, Block A, 35 to 375C Temperature Range, 115VSince we introduced the worlds first truly handheld dry-well, many have tried to duplicate itin vain. Despite its small size (2 inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world. Its simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375C (707F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.Detailed Description LessBrandFlukeMfr. Part#9100S-C-156Customer Part#Campbell Part# FLU9100S-C-156
- Handheld Dry-Well Hi-Temperature Calibrator, Block A, 35 to 375?C Temperature Range, 115VSince we introduced the worlds first truly handheld dry-well, many have tried to duplicate itin vain. Despite its small size (2 inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world. Its simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375C (707F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.Detailed Description LessBrandFlukeMfr. Part#9100S-D-156Customer Part#Campbell Part# FLU9100S-D-156
- HDRC Handheld Dry-Well Low-Temperature Calibrator, -10 to 122?C Temperature Range, 94-234VFluke Calibration Hdrc Handheld Dry-well Low-temperature Calibrator, -10 To 122degrees Celsius Temperature Range, 94-234vDetailed Description LessBrandFlukeMfr. Part#9102S-156Customer Part#Campbell Part# FLU9102S-156
- Drywell Temperature Pressure Calibrator With Type A Insert, -25 To 140 deg c Temperature Range, 115vCovers Below-ambient Temperatures As Low As ?25 Degrees Celsius. The 9140, Weighing Only 2,7 Kg, Has A Temperature Range Of 35 Degrees Celsius To 350 Degrees Celsius And Reaches Its Maximum Temperature In 12 Minutes. Lightweight And Very Portable. Accuracy To 0.25 Degrees Celsius. Rs-232 And Interface-it Software Included. Insert A Handles A Full Range Of Probe Sizes With A Single Well Of Each Size.Detailed Description LessBrandFlukeMfr. Part#9103-A-156Customer Part#Campbell Part# FLU9103-A-156
- Field Dry-well Calibrator With Insert B (3103-3) NistCovers Below-ambient Temperatures As Low As ?25 Degrees Celsius. The 9140, Weighing Only 2,7 Kg, Has A Temperature Range Of 35 Degrees Celsius To 350 Degrees Celsius And Reaches Its Maximum Temperature In 12 Minutes. Lightweight And Very Portable. Accuracy To 0.25 Degrees Celsius. Rs-232 And Interface-it Software Included. Insert B Features Two Wells Each Of 3/8, 1/4, And 3/16 Inches In Diameter For Doing Comparison Calibrations.Detailed Description LessBrandFlukeMfr. Part#9103-B-156Customer Part#Campbell Part# FLU9103-B-156
- Field Dry-well Calibrator With Insert (3103-4) 110v, 50/60hzCovers Below-ambient Temperatures As Low As ?25 Degrees Celsius. The 9140, Weighing Only 2,7 Kg, Has A Temperature Range Of 35 Degrees Celsius To 350 Degrees Celsius And Reaches Its Maximum Temperature In 12 Minutes. Lightweight And Very Portable. Accuracy To 0.25 Degrees Celsius. Rs-232 And Interface-it Software Included. Insert C Has Six 1/4-inch-diameter Wells For Multiple Probe Calibrations.Detailed Description LessBrandFlukeMfr. Part#9103-C-156Customer Part#Campbell Part# FLU9103-C-156
- Dry-well, -25c Field With 3103-6, 115vCovers Below-ambient Temperatures As Low As ?25 Degrees Celsius. The 9140, Weighing Only 2,7 Kg, Has A Temperature Range Of 35 Degrees Celsius To 350 Degrees Celsius And Reaches Its Maximum Temperature In 12 Minutes. Lightweight And Very Portable. Accuracy To 0.25 Degrees Celsius. Rs-232 And Interface-it Software Included. Insert D Has Three Pairs Of Metric Sized Wells.Detailed Description LessBrandFlukeMfr. Part#9103-D-156Customer Part#Campbell Part# FLU9103-D-156
- High-temperature Dry-well Field Calibrator, No Insert, 115vCovers Below-ambient Temperatures As Low As ?25 Degrees Celsius. The 9103 Is Stable To Plus Or Minus0.02 Degrees Celsius, And Its Display Is Calibrated ToDetailed Description LessBrandFlukeMfr. Part#9103-DW-156Customer Part#Campbell Part# FLU9103-DW-156
- Field Dry-well Calibrator With Insert A (3140-2), 35c To 350cMay Be Used As A Portable Instrument Or Bench Top Temperature Calibrator For Calibrating Thermocouple And Rtd Temperature Probes. It Is Small Enough To Use In The Field, And Accurate Enough To Use In The Lab. The Temperature Is Accurately Controlled By Harts Hybrid Analog/digital Controller. The Controller Uses A Precision Platinum Rtd As A Sensor And Controls The Well Temperature With A Solid State Relay (triac) Driven Heater. The Led Front Panel Continuously Shows The Current Well Temperature. The Temperature May Be Easily Set With The Control Buttons To Any Desired Temperature Within The Specified Range. The Instruments Multiple Fault Protection Devices Insure User And Instrument Safety And Protection. The Dry-well Calibrator Was Designed For Portability, Low Cost, And Ease Of Operation. Through Proper Use The Instrument Will Provide Continued Accurate Calibration Of Temperature Sensors And Devices. Insert A (variety Block): 1/2", 3/8",3/16",1/8", And 1/16" Holes.Detailed Description LessBrandFlukeMfr. Part#9140-A-156Customer Part#Campbell Part# FLU9140-A-156
- Field Dry-well Calibrator With Insert B (3140-3), 35c To 350cMay Be Used As A Portable Instrument Or Bench Top Temperature Calibrator For Calibrating Thermocouple And Rtd Temperature Probes. It Is Small Enough To Use In The Field, And Accurate Enough To Use In The Lab. The Temperature Is Accurately Controlled By Hart?s Hybrid Analog/digital Controller. The Controller Uses A Precision Platinum Rtd As A Sensor And Controls The Well Temperature With A Solid State Relay (triac) Driven Heater. The Led Front Panel Continuously Shows The Current Well Temperature. The Temperature May Be Easily Set With The Control Buttons To Any Desired Temperature Within The Specified Range. The Instrument?s Multiple Fault Protection Devices Insure User And Instrument Safety And Protection. The Dry-well Calibrator Was Designed For Portability, Low Cost, And Ease Of Operation. Through Proper Use The Instrument Will Provide Continued Accurate Calibration Of Temperature Sensors And Devices. Insert B (comparison Block): 2 3/8",2 1/4", And 2 3/16" Holes.Detailed Description LessBrandFlukeMfr. Part#9140-B-156Customer Part#Campbell Part# FLU9140-B-156
- Field Dry-well Calibrator With Insert C(3140-4), 110v, 50/60hzMay Be Used As A Portable Instrument Or Bench Top Temperature Calibrator For Calibrating Thermocouple And Rtd Temperature Probes. It Is Small Enough To Use In The Field, And Accurate Enough To Use In The Lab. The Temperature Is Accurately Controlled By Hart?s Hybrid Analog/digital Controller. The Controller Uses A Precision Platinum Rtd As A Sensor And Controls The Well Temperature With A Solid State Relay (triac) Driven Heater. The Led Front Panel Continuously Shows The Current Well Temperature. The Temperature May Be Easily Set With The Control Buttons To Any Desired Temperature Within The Specified Range. The Instrument?s Multiple Fault Protection Devices Insure User And Instrument Safety And Protection. The Dry-well Calibrator Was Designed For Portability, Low Cost, And Ease Of Operation. Through Proper Use The Instrument Will Provide Continued Accurate Calibration Of Temperature Sensors And Devices. Insert C (1/4" Comparison Block): 6 1/4" Holes.Detailed Description LessBrandFlukeMfr. Part#9140-C-156Customer Part#Campbell Part# FLU9140-C-156
- Mid-range Field Dry-well Cali. With Insert (3140-6,115v)Has A Temperature Range Of 35 To 350 Degrees Celsius, And It Reaches Its Maximum Temperature In 12 Minutes. At Six Pounds, It's Small Enough To Easily Carry In One Hand. It's Truly A Unique Innovation In Dry-wells. The Unit Has A Stability Of Plus Or Minus0.05 Degrees Celsius Or Better And A Uniformity Of At Least 0.4 Degrees Celsius In The Largest-diameter Wells And 0.1 Degrees Celsius In The Smaller Wells. Despite Its Small Size, This Unit Performs. Use The Display, Calibrated To Plus Or Minus0.5 Degrees Celsius, As Your Reference, Or Use An External Thermometer For Maximum Calibration Accuracy. With Three Removable Inserts To Choose From, It Is As Versatile As It Is Fast. Dry-well, Mid-range Field W/3140-6, 115v.Detailed Description LessBrandFlukeMfr. Part#9140-D-156Customer Part#Campbell Part# FLU9140-D-156
- Mid-range Field Dry-well Cali. No Insert, 115vHas A Temperature Range Of 35 Degrees Celsius To 350 Degrees Celsius, And It Reaches Its Maximum Temperature In 12 Minutes.at Six Pounds, It?s Small Enough To Easily Carry In One Hand. It?s Truly A Unique Innovation In Dry-wells.Detailed Description LessBrandFlukeMfr. Part#9140-DW-156Customer Part#Campbell Part# FLU9140-DW-156
- Low-temperature Dry-well Field Calibrator With 9142-insa, 115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insa. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading.Detailed Description LessBrandFlukeMfr. Part#9142-A-156Customer Part#Campbell Part# FLU9142-A-156
- Dry-well Field Calibrator, 115v With 9142-insa & Built-in Elct.Temp. Range -25 To 150degrees Celsius (-13 To 302degrees Fahrenheit). Compact Size And Light Weight Enable Easy Portability In The Field. Built-in Reference Thermometer Accuracy To Plus Or Minus0.01degrees Celsius Eliminates The Need To Carry A Separate Process Calibrator. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. Insert A: 3/8, Three 1/4, 3/16, 1/8Detailed Description LessBrandFlukeMfr. Part#9142-A-P-156Customer Part#Campbell Part# FLU9142-A-P-156
- Low-temperature Dry-well Field Calibrator With 9142-insb, 115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insb. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert B: Two 3/8, Two 1/4, Two 3/16Detailed Description LessBrandFlukeMfr. Part#9142-B-156Customer Part#Campbell Part# FLU9142-B-156
- Dry-well Field Calibrator, 115v With 9142-insb & Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insb. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. Insert B: Two 3/8, Two 1/4, Two 3/16Detailed Description LessBrandFlukeMfr. Part#9142-B-P-156Customer Part#Campbell Part# FLU9142-B-P-156
- Low-temperature Dry-well Field Calibrator With 9142-insc, 115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insc. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert C: Six 1/4Detailed Description LessBrandFlukeMfr. Part#9142-C-156Customer Part#Campbell Part# FLU9142-C-156
- Carrying Case For 9142-4 Strong, Lightweight Resin ShellFluke Calibration (hart Scientific) : Carrying Case, 9142-9144Detailed Description LessBrandFlukeMfr. Part#9142-CASECustomer Part#Campbell Part# FLU9142-CASE
- Dry-well Field Calibrator, 115v With 9142-insc & Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insc. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. Insert C: Six 1/4Detailed Description LessBrandFlukeMfr. Part#9142-C-P-156Customer Part#Campbell Part# FLU9142-C-P-156
- Low-temperature Dry-well Field Calibrator With 9142-insd, 115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insd. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert D: Two 6mm, Two 4mm, Two 3mmDetailed Description LessBrandFlukeMfr. Part#9142-D-156Customer Part#Campbell Part# FLU9142-D-156
- Dry-well Field Calibrator, 115v With 9142-insd & Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insd. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. Insert D: Two 6mm, Two 4mm, Two 3mmDetailed Description LessBrandFlukeMfr. Part#9142-D-P-156Customer Part#Campbell Part# FLU9142-D-P-156
- Low-temperature Dry-well Field Calibrator, No Insert, 115v?25 Degrees Celsius To 150 Degrees Celsius. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. No Inserts Included.Detailed Description LessBrandFlukeMfr. Part#9142-DW-156Customer Part#Campbell Part# FLU9142-DW-156
- Dry-well Field Calibrator, 115v No Insert, With Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. No Inserts Included.Detailed Description LessBrandFlukeMfr. Part#9142-DW-P-156Customer Part#Campbell Part# FLU9142-DW-P-156
- Low-temperature Dry-well Field Calibrator With 9142-inse, 115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-inse. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert E: 10mm, 8mm, 6mm, 1/4, 4mm, 3mmDetailed Description LessBrandFlukeMfr. Part#9142-E-156Customer Part#Campbell Part# FLU9142-E-156
- Field Metrology Dry-well Calibrator With Type A Insert And Process Electronics, -25 To 150?c Temperature Range,115v?25 Degrees Celsius To 150 Degrees Celsius, With 9142-inse. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In -p Model Only. Insert E: 10mm, 8mm, 6mm, 1/4, 4mm, 3mmDetailed Description LessBrandFlukeMfr. Part#9142-E-P-156Customer Part#Campbell Part# FLU9142-E-P-156
- Dry-well Field Calibrator, 115v With 9142-insf & Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insf. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert F: 6mm, 1/4, Two 4mm, Two 3mmDetailed Description LessBrandFlukeMfr. Part#9142-F-156Customer Part#Campbell Part# FLU9142-F-156
- Dry-well Field Calibrator, 115v With 9142-insf & Built-in Elct.?25 Degrees Celsius To 150 Degrees Celsius, With 9142-insf. Lightweight, Portable, And Fast. Cool To ?25 Degrees Celsius In 15 Minutes And Heat To 660degrees Celsius In 15 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, And Clamp-on Ferrites (3) In P Model Only. Insert F: 6mm, 1/4, Two 4mm, Two 3mm.Detailed Description LessBrandFlukeMfr. Part#9142-F-P-156Customer Part#Campbell Part# FLU9142-F-P-156
- Mid-temperature Dry-well Field Calibrator With 9143-insa, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert A: 3/8", 3/16", 1/8"Detailed Description LessBrandFlukeMfr. Part#9143-A-156Customer Part#Campbell Part# FLU9143-A-156
- Dry-well Field Calibrator, 115v With 9143-insa & Built-in Elct.t33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert A: 3/8", 3/16", 1/8" 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In P Model Only.Detailed Description LessBrandFlukeMfr. Part#9143-A-P-156Customer Part#Campbell Part# FLU9143-A-P-156
- Mid-temperature Dry-well Field Calibrator With 9143-insb, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert B: 3/8", Two 3/16", 1/8"Detailed Description LessBrandFlukeMfr. Part#9143-B-156Customer Part#Campbell Part# FLU9143-B-156
- Dry-well Field Calibrator, 115v With 9143-insb & Built-in Elct.33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert B: 3/8", Two 3/16", 1/8" 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In P Model Only.Detailed Description LessBrandFlukeMfr. Part#9143-B-P-156Customer Part#Campbell Part# FLU9143-B-P-156
- Mid-temperature Dry-well Field Calibrator With 9143-insc, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert C: FourDetailed Description LessBrandFlukeMfr. Part#9143-C-156Customer Part#Campbell Part# FLU9143-C-156
- Dry-well Field Calibrator, 115v With 9143-insc & Built-in Elct.33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert C: Four 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In P Model Only.Detailed Description LessBrandFlukeMfr. Part#9143-C-P-156Customer Part#Campbell Part# FLU9143-C-P-156
- Mid-temperature Dry-well Field Calibrator With 9143-insa, 115v D33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert D: Two 6mm, Two 4mm, Two 3mm.Detailed Description LessBrandFlukeMfr. Part#9143-D-156Customer Part#Campbell Part# FLU9143-D-156
- Calibrator; Field Metrology Well; Insert D; 33 To 350 C; Process Electronics33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert D: Two 6mm, Two 4mm, Two 3mm 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In ?p Model Only.Detailed Description LessBrandFlukeMfr. Part#9143-D-P-156Customer Part#Campbell Part# FLU9143-D-P-156
- Mid-temperature Dry-well Field Calibrator, No Insert, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. No Insert.Detailed Description LessBrandFlukeMfr. Part#9143-DW-156Customer Part#Campbell Part# FLU9143-DW-156
- Dry-well Field Calibrator, 115v No Insert With Built-in Elct.33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In ?p Model Only, No Insert.Detailed Description LessBrandFlukeMfr. Part#9143-DW-P-156Customer Part#Campbell Part# FLU9143-DW-P-156
- Mid-temperature Dry-well Field Calibrator With 9143-inse, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert E: 10mm, 8mm, 6mm, 4mm.Detailed Description LessBrandFlukeMfr. Part#9143-E-156Customer Part#Campbell Part# FLU9143-E-156
- Dry-well Field Calibrator, 115v With 9143-inse & Built-in Elct.33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert E: 10mm, 8mm, 6mm, 4mm 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In P Model Only.Detailed Description LessBrandFlukeMfr. Part#9143-E-P-156Customer Part#Campbell Part# FLU9143-E-P-156
- Dry-well, Mid-temp Field, W/9143-insf, 115v33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert F: 6mm, 1/4", Two 4mm, Two 3mmDetailed Description LessBrandFlukeMfr. Part#9143-F-156Customer Part#Campbell Part# FLU9143-F-156
- Dry-well, Field, W/9143-insf, W/built-in Elct.33 To 350 Degrees Celsius (91 To 662degrees Fahrenheit) Lightweight, Portable, And Fast. Cool To 33 Degrees Celsius In 32 Minutes And Heat To 350 Degrees Celsius In 5 Minutes. Built-in Two-channel Readout For Prt, Rtd, Thermocouple, 4-20 Ma Current. True Reference Thermometry With Accuracy To Plus Or Minus 0.01 Degrees Celsius. On-board Automation And Documentation. Metrology Performance In Accuracy, Stability, Uniformity, And Loading. Insert F: 6mm, 1/4", Two 4mm, Two 3mm 6-pin Din Connector, Test Lead Kit, Clamp-on Ferrites (3) In P Model OnlyDetailed Description LessBrandFlukeMfr. Part#9143-F-P-156Customer Part#Campbell Part# FLU9143-F-P-156
- High Temperature Field Metrology Well Calibrator With Process Electronics, 50 deg c To 660 deg c Range, 115vMetrology Well: Lightweight, Portable, And Fast Insert A, Imperial Misc. Holes , 50 Deg C To 660 Deg C, W/ 9144-insx, W/ Process Electronics.Detailed Description LessBrandFlukeMfr. Part#9144-A-156Customer Part#Campbell Part# FLU9144-A-156
- High Temperature Field Metrology Well Calibrator With Process Electronics, 50 deg c To 660 deg c Range, 115vMetrology Well: Lightweight, Portable, And Fast Insert A, Imperial Misc. Holes , 50 Deg C To 660 Deg C, W/ 9144-insx, W/ Process Electronics. Includes Test Leads, And 6-pin Din Connector For Reference Probe.Detailed Description LessBrandFlukeMfr. Part#9144-A-P-156Customer Part#Campbell Part# FLU9144-A-P-156
- Series 9144 High Temperature Field Metrology Well Calibrator With 9144 Type B Insert, 50 deg c To 660 deg c Range, 115vMetrology Well: Lightweight, Portable, And Fast Insert B, Imperial Comparison Holes, 50 Deg C To 660 Deg C, W/ 9144-insx, W/ Process Electronics.Detailed Description LessBrandFlukeMfr. Part#9144-B-156Customer Part#Campbell Part# FLU9144-B-156