- Oil Deadweight Tester Dual Range 1100 BarOil Operated - Dual Pcu; Pressure Range 1 To 1,100 Bar; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Bmineral Oil And Distilled Water Models; Dual Piston Models Allow Calibration Over A Wide Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125-BARCustomer Part#Campbell Part# FLUP3125-BAR
- Oil Deadweight Tester Dual Range 1100 Kgf/cm2Oil Operated - Dual Pcu; Pressure Range 1 To 1 100 Kgf/cm?; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Bmineral Oil And Distilled Water Models; Dual Piston Models Allow Calibration Over A Wide Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125-KGCM2Customer Part#Campbell Part# FLUP3125-KGCM2
- Oil Deadweight Tester Dual Range 110 MpaOil Operated - Dual Pcu; Pressure Range 0.1 To 110 Mpa; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Bmineral Oil And Distilled Water Models; Dual Piston Models Allow Calibration Over A Wide Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125-MPACustomer Part#Campbell Part# FLUP3125-MPA
- Oil Deadweight Tester Dual Range 16000 PsiOil Operated - Dual Pcu; Pressure Range 10 To 16 000 Psi; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Bmineral Oil And Distilled Water Models; Dual Piston Models Allow Calibration Over A Wide Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125-PSICustomer Part#Campbell Part# FLUP3125-PSI
- Oil Deadweight Tester Dual Range 1200 BarHydraulic Deadweight Tester - Oil Operated - Dual Pcu; Pressure Range 1 To 1200 Bar; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Mineral Oil And Distilled Water Models; Dual Piston Models For Calibration Over A Wide Pressure RangeDetailed Description LessBrandFlukeMfr. Part#P3125XT-BARCustomer Part#Campbell Part# FLUP3125XT-BAR
- Oil Deadweight Tester Dual Range 1200 Kgf/cm2Oil Operated - Dual Pcu; Pressure Range 1 To 1200 Kgf/cm2; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Mineral Oil And Distilled Water Models; Dual Piston Models For Calibration Over A Wide Pressure Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125XT-KGCM2Customer Part#Campbell Part# FLUP3125XT-KGCM2
- Oil Deadweight Tester Dual Range 120 MpaOil Operated - Dual Pcu; Pressure Range 1 To 120 Mpa; Accuracy Better Than 0.015 % Of Reading (increased Accuracy Option Of 0.008 %); Mineral Oil And Distilled Water Models; Dual Piston Models For Calibration Over A Wide Pressure Range; Psi, Bar, Kgf/cm2 , Kpa And Mpa Ranges AvailableDetailed Description LessBrandFlukeMfr. Part#P3125XT-MPACustomer Part#Campbell Part# FLUP3125XT-MPA
- Water Deadweight Tester, 35 BarWater Operated ? Single Pcu; Pressure Range 1 To 35 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3211-BARCustomer Part#Campbell Part# FLUP3211-BAR
- Water Deadweight Tester, 35 Kgf/cm2Water Operated ? Single Pcu; Pressure Range 1 To 35 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3211-KGCM2Customer Part#Campbell Part# FLUP3211-KGCM2
- Water Deadweight Tester, 3500 KpaWater Operated ? Single Pcu; Pressure Range 100 To 3,500 Kpa; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3211-KPACustomer Part#Campbell Part# FLUP3211-KPA
- Water Deadweight Tester, 3.5 MpaWater Operated ? Single Pcu; Pressure Range 0.1 To 3.5 Mpa; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3211-MPACustomer Part#Campbell Part# FLUP3211-MPA
- Water Deadweight Tester, 500 PsiWater Operated ? Single Pcu; Pressure Range 10 To 500 Psi; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3211-PSICustomer Part#Campbell Part# FLUP3211-PSI
- Water Deadweight Tester, 350 BarWater Operated ? Single Pcu; Pressure Range 10 To 350 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3213-BARCustomer Part#Campbell Part# FLUP3213-BAR
- Water Deadweight Tester 350 Kgf/cm2Water Operated ? Single Pcu; Pressure Range 10 To 350 Kgf/cm?; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3213-KGCM2Customer Part#Campbell Part# FLUP3213-KGCM2
- Water Deadweight Tester, 35 MpaWater Operated ? Single Pcu; Pressure Range 1 To 35 Mpa; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3213-MPACustomer Part#Campbell Part# FLUP3213-MPA
- Water Deadweight Tester 5000 PsiWater Operated ? Single Pcu; Pressure Range 100 To 5,000 Psi; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3213-PSICustomer Part#Campbell Part# FLUP3213-PSI
- Water Deadweight Tester 700 BarWater Operated ? Single Pcu; Pressure Range 20 To 700 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3214-BARCustomer Part#Campbell Part# FLUP3214-BAR
- Water Deadweight Tester 700 Kgf/cm2Water Operated ? Single Pcu; Pressure Range 20 To 700 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable FeetDetailed Description LessBrandFlukeMfr. Part#P3214-KGCM2Customer Part#Campbell Part# FLUP3214-KGCM2
- Water Deadweight Tester 70 MpaWater Operated ? Single Pcu; Pressure Range 2 To 70 Mpa; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3214-MPACustomer Part#Campbell Part# FLUP3214-MPA
- Water Deadweight Tester 10k PsiWater Operated ? Single Pcu; Pressure Range 200 To 10,000 Psi; 0.015% Of Reading Accuracy Standard (0.008% Optional); Single Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3214-PSICustomer Part#Campbell Part# FLUP3214-PSI
- Water Deadweight Tester Dual Range 350 BarWater Operated ? Dual Pcu; Pressure Range 1 To 350 Bar; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3223-BARCustomer Part#Campbell Part# FLUP3223-BAR
- Water Deadweight Tester Dual Range 350 Kgf/cm2Water Operated ? Dual Pcu; Pressure Range 1 To 350 Kgf/cm?; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3223-KGCM2Customer Part#Campbell Part# FLUP3223-KGCM2
- Water Deadweight Tester Dual Range 35 MpaWater Operated ? Dual Pcu; Pressure Range 0.1 To 35 Mpa; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3223-MPACustomer Part#Campbell Part# FLUP3223-MPA
- Water Deadweight Tester Dual Range 5000 PsiWater Operated ? Dual Pcu; Pressure Range 1 To 700 Kgf/cm?; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3223-PSICustomer Part#Campbell Part# FLUP3223-PSI
- Water Deadweight Tester Dual Range 700 BarWater Operated ? Dual Pcu; Pressure Range 1 To 700 Kgf/cm?; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3224-BARCustomer Part#Campbell Part# FLUP3224-BAR
- Water Deadweight Tester Dual Range 700 Kgf/cm2Water Operated ? Dual Pcu; Pressure Range 1 To 700 Kgf/cm?; 0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3224-KGCM2Customer Part#Campbell Part# FLUP3224-KGCM2
- Water Deadweight Tester Dual Range 70 Mpa0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3224-MPACustomer Part#Campbell Part# FLUP3224-MPA
- Water Deadweight Tester Dual Range 10k Psi0.015% Of Reading Accuracy Standard (0.008% Optional); Dual Piston Formats; Built-in Hand Pumps Standard; Mounted Spirit Level With Adjustable Feet; Units Can Be Trimmed To Local Gravity FocDetailed Description LessBrandFlukeMfr. Part#P3224-PSICustomer Part#Campbell Part# FLUP3224-PSI