How can we get better? Print

True Rms Clamp-meter, 2,000a Ac/dc, Conductors To 58mm, Voltage, Frequency, And Resistance Measurement

Digital Clamp Meter, Model: 355, Voltage Rating: 1000 Vac/vdc Maximum, Amperage Rating: 1400 Amp Ac (maximum), 2000 Amp Dc (maximum), Resistance: 4/40/400 Kohm, Accuracy: 1.5 Pct Rdg Plus 15 Digits And 1.5 Pct Rdg Plus 5 Digits At Current Measurement Dc And Ac 10 - 100 Hz 10 A: 3.5 Pct Rdg Plus 15 Digits, 10 A: 3.5 Pct Rdg Plus 5 Digits At Current Measurement Ac 100.1 Hz To 1 Khz 1 Pct Rdg Plus 10 Digits 1 Pct Rdg Plus 5 Digits At Voltage Measurement Dc And Ac 10 - 100 Hz 3 Pct Rdg Plus 10 Digits, 3 Pct Rdg Plus 5 Digits At Voltage Measurement Ac 100.1 Hz To 1 Khz 1.5 Pct Rdg Plus 5 Digits At Resistance Measurement 0.2 Pct Plus 2 Counts (5 - 100 Hz) And 0.5 Pct Plus 5 Counts (100.1 Hz - 1 Khz) At Frequency Measurement, Temperature Rating: 32 - 122 Deg F, Battery: (6) 1.5 V Aa Neda 15 Amp Or Iec Lr6, Enclosure: Ip42, Dimensions: 12 In Length, Resolution: 10/100/1000 Milamp At Current Measurement Dc And Ac 10 - 100 Hz 10/100/1000 Milamp At Current Measurement Ac 100.1 Hz - 1 Khz 1/10/100/1000 Milv At Voltage Measurement Dc And Ac 10 - 100 Hz 1/10/100/1000 Milv At Voltage Measurement Ac 100.1 Hz - 1 Khz 0.1/1/10/100 Ohm At Resistance Measurement 0.1 Hz (15 - 399.9 Hz), 1 Hz (400 Hz - 1 Khz) At Frequency Measurement, Measuring Range: 40 /400/2000 Amp 1400 Ac Rms At Current, Crest Factor (50/60 Hz) And Current Measurement Ac 100.1 Hz - 1 Khz 4/40/400 V, 600 Vac Rms/1000 Vdc At Voltage Measurement Dc And Ac 10 - 100 Hz 4/40/400 V, 600 Vac Rms At Voltage Measurement Ac 100.1 Hz - 1 Khz 4/40/400 Kohm At Resistance 5 Hz - 1 Khz At Frequency, Storage Temperature: -4 To 140 Deg F, Ce Certified, C/us Csa Certified, N10140 Confirmed, Cat Iv 600 V, Cat Iii 1000 V, Iec 61010-2-032, 600 V Cat Iv, 1000 V Cat Iii Emi, Rfi, Emc: Fcc Part 15, Iec/en 61326-1:1997 Class B Iec/en 61326:1997 3 V/m, Performance Criteria B, En61325, For Utilities, Electrical Contractors And Industrial Service Technicians
Brand
Fluke
Mfr. Part#
FLUKE-355
Campbell Part#
FLUFLUKE-355
Qty:
Min. Qty:
1 ea
Qty Intervals:
1 ea
$1,077.99 ea
Est. Lead Time: 20 Bus. Days
More Information
Accuracy1.5 PCT RDG Plus 15 Digits And 1.5 PCT RDG Plus 5 Digits At Current Measurement DC And AC 10 - 100 HZ; 10 A: 3.5 PCT RDG Plus 15 Digits, 10 A: 3.5 PCT RDG Plus 5 Digits At Current Measurement AC 100.1 HZ To 1 KHZ; 1 PCT RDG Plus 10 Digits; 1 PCT RDG Plus 5 Digits At Voltage Measurement DC And AC 10 - 100 HZ; 3 PCT RDG Plus 10 Digits, 3 PCT RDG Plus 5 Digits At Voltage Measurement AC 100.1 HZ To 1 KHZ; 1.5 PCT RDG Plus 5 Digits At Resistance Measurement; 0.2 PCT Plus 2 Counts (5 - 100 HZ) And 0.5 PCT Plus 5 Counts (100.1 HZ - 1 KHZ) At Frequency Measurement
Amperage Rating1400 AMP AC (Maximum), 2000 AMP DC (Maximum)
ApplicationFor Utilities, Electrical Contractors And Industrial Service Technicians
Battery(6) 1.5 V AA NEDA 15 AMP Or IEC LR6
Model355
Resistance4/40/400
Special FeaturesThe tools of choice for high current clamp-on amp meter measurement up to 2000 AMP; The extra-wide jaw easily clamps around large conductors, typically found in high-current applications; The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements; Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads; The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians; Reliably handle a wide range of high-current applications with 2000 AMP AC plus DC true-rms, 1400 AMP AC and 2000 AMP DC; The large 58 MM jaw capacity is suitable for large or multiple conductors; CAT IV 600 V, CAT III 1000 V rating for added user protection; In-rush current measurement captures power-on? surge current with accuracy and repeatability; High voltage measurement of 1000 VAC plus VDC true-rms, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only); Resistance to 400 KOHM coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only); Accurately measure frequency up to 1 KHZ for optimum troubleshooting; Quickly analyze readings using the minimum, maximum and average functions; A large backlit display allows for easy visibility in low-lit areas; Use the display hold feature to capture readings even when the display cannot be viewed; Use the low-pass filter to smooth out noisy loads and stabilize readings; Jaw capacity: 2-5/16 IN; Battery type: AA; AC response: TRMS; Audible continuity; Auto ranging; Data hold; Inrush and auto power off; Operating humidity: 0 - 95 PCT (non-condensing); Altitude: 2000 MR (operating ) and 10000 MR (Storage ); Drop test requirements 1 M; Temperature coefficients: 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (current), 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (voltage); Battery life (with typical usage, backlight off): 100 HR; Test leads rated to 1000 V; Weight: 1.8 LB; Jaw size: 58 MM; 3.75 IN Width X 2 IN Depth
StandardCE Certified, C/US CSA Certified, N10140 Confirmed, CAT IV 600 V, CAT III 1000 V, IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III EMI, RFI, EMC: FCC Part 15, IEC/EN 61326-1:1997 Class B IEC/EN 61326:1997 3 V/M, Performance Criteria B, EN61325
Temperature Rating32 - 122
Voltage Rating1000 VAC/VDC Maximum
Specification Sheet