- 125VAC 20 Ampere Pin/Sleeve PlugPin and Sleeve Plug; Brand Name ArkGard; Voltage Rating 125 VAC; Current Rating 20 Ampere; Minimum Cable Outer Diameter 0.54 Inch; Maximum Cable Outer Diameter 0.635 Inch; Material Aluminum Acrylic Painted Die Cast Copper Free Aluminum; Mating Receptacle ENRC; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group F G, Class III, NEMA 3/7BCD/9FG/12; Approval UL, CSADetailed Description LessBrandCrouse-HindsMfr. Part#ENP5201Customer Part#Campbell Part# CROENP5201
- 125VAC 20 Ampere Copper Free Aluminum Pin/Sleeve ReceptaclePin and Sleeve Receptacle; Brand Name ArkGard; Type Single Gang EDS; Voltage Rating 125 VAC; Current Rating 20 Ampere; Cover Type Spring; Material Aluminum Acrylic Painted Die Cast Copper Free Aluminum; Mating Plug ENP; Enclosure Class I Div 1 and 2 Group C D, Class II Div 1 and 2 Group F G, Class III, NEMA 3/7CD/9FG/12; Approval UL, CSA; Hub Size 1 InchDetailed Description LessBrandCrouse-HindsMfr. Part#ENR5201Customer Part#Campbell Part# CROENR5201
- 125VAC 15 Ampere Pin/Sleeve PlugPin and Sleeve Plug; Brand Name U-Line, Interchanger; Voltage Rating 125 VAC; Current Rating 15 Ampere; Power Rating 1 HP; Number Of Phases 3; Number Of Poles 3; Number Of Wires 2; Minimum Cable Outer Diameter 0.538 Inch; Maximum Cable Outer Diameter 0.639 Inch; Material Copper Free Aluminum; Mating Receptacle ECSK; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group G and Coal Dust, Class III, Type 7BCD/9G; Approval CSA; Size 1.75 Inch W x 2.78 Inch HDetailed Description LessBrandAppletonMfr. Part#ECP1523Customer Part#Campbell Part# APPECP1523
- 125VAC 20 Ampere Pin/Sleeve PlugPin and Sleeve Plug; Brand Name U-Line, Interchanger; Voltage Rating 125 VAC; Current Rating 20 Ampere; Power Rating 1 HP; Number Of Phases 3; Number Of Poles 3; Number Of Wires 2; Minimum Cable Outer Diameter 0.538 Inch; Maximum Cable Outer Diameter 0.639 Inch; Material Copper Free Aluminum; Mating Receptacle ECSK; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group G and Coal Dust, Class III, Type 7BCD/9G; Approval CSA; Size 1.75 Inch W x 2.78 Inch HDetailed Description LessBrandAppletonMfr. Part#ECP2023Customer Part#Campbell Part# APPECP2023
- 250VAC 15/20 Ampere Copper Free Aluminum Device Mounting BoxPin and Sleeve Device Mounting Box; Brand Name U-Line; Type Front Opening; Device Rating 250 VAC 15/20 Ampere; Body Material Copper Free Aluminum; Number of Mounting Lugs 2; Hub Size 3/4 Inch; Approval CSA; Used On ECS Series U-Line Factory Sealed Pin and Sleeve Device; Size 3.75 Inch W x 3 Inch D x 6.62 Inch H; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group G and Coal Dust, Class III, CSA Type 7BCD/9GDetailed Description LessBrandAppletonMfr. Part#ECS175Customer Part#Campbell Part# APPECS175
- 125VAC 20 Ampere Copper Free Aluminum Pin/Sleeve ReceptaclePin and Sleeve Receptacle/Cover Assembly; Brand Name U-Line; Type Single Gang/Two Gang ECS; Voltage Rating 125 VAC; Current Rating 20 Ampere; Power Rating 1 HP; Number Of Poles 2; Number Of Wires 3; Cover Type Spring; Material Epoxy Powder Coated Copper Free Aluminum; Mating Plug ECP; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group G and Coal Dust, Class III, CSA Type 7BCD/9G; Approval CSA C22.2; Depth 3 InchDetailed Description LessBrandAppletonMfr. Part#ECSK2023Customer Part#Campbell Part# APPECSK2023
- 120 To 277VAC 20 Ampere Snap Switch Control StationSnap Switch Control Station; Brand Name UNILETS; Constructional Feature Explosionproof, Dust-Ignitionproof; Voltage Rating 120 to 277 VAC; Current Rating 20 Ampere; Contact Configuration 1 Pole; Operator Type Front Operated; Enclosure Material Electro Zinc Plated Chromate and Epoxy Powder Coated Malleable Iron; Enclosure Class I Div 1 and 2 Group C D, Class II Div 1 and 2 Group E F G, Class III, NEMA 7CD/9EFG; Approval UL 894, UL 1203Detailed Description LessBrandAppletonMfr. Part#EDKF21QCustomer Part#Campbell Part# APPEDKF21Q
- 600VAC 10 Ampere Pushbutton Control StationPushbutton Control Station; Brand Name Contender; Type Feed Through; Constructional Feature Explosionproof, Dust-Ignitionproof; Voltage Rating 600 VAC; Current Rating 10 Ampere; Legend Start-Stop; Number Of Elements 2; Number Of Circuits 2; Contact Configuration 2NO-2NC, Universal; Operator Type Front Operated Button; Box Type Single Gang; Hub Size 3/4 Inch; Enclosure Material Electro Zinc Plated Chromate and Epoxy Powder Coated Malleable Iron; Enclosure Class I Div 1 Group C D, Class I Div 2 Group B C D, Class II Div 1 and 2 Group E F G, Class III, NEMA 3/7BCD/9EFG; Approval ULDetailed Description LessBrandAppletonMfr. Part#EDSC2190Customer Part#Campbell Part# APPEDSC2190
- 600VAC Pushbutton Control StationPushbutton Control Station; Constructional Feature Explosionproof, Dust-Ignitionproof, Rain Tight, Wet Location; Voltage Rating 600 VAC; Number of Elements 2; Number of Circuits 2; Contact Configuration 1NO-1NC, Universal; Operator Type Front Operated Button; Enclosure Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group F G, Class III, NEMA 3/7BCD/9EFG; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#DSD921Customer Part#Campbell Part# CRODSD921
- 120 To 277VAC 20 Ampere Snap Switch Control StationSnap Switch Control Station; Constructional Feature Explosionproof, Dust-Ignitionproof, Rain Tight, Wet Location; Voltage Rating 120 to 277 VAC; Current Rating 20 Ampere; Contact Configuration 1 Pole; Operator Type Front Operated; Box Type Single Gang; Enclosure Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group F G, Class III, NEMA 3/7BCD/9EFG; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#DSD933Customer Part#Campbell Part# CRODSD933
- 120 To 277VAC 20 Ampere Snap Switch Control StationSnap Switch Control Station; Constructional Feature Explosionproof, Dust-Ignitionproof, Rain Tight, Wet Location; Voltage Rating 120 to 277 VAC; Current Rating 20 Ampere; Contact Configuration 2 Pole; Operator Type Front Operated; Box Type Single Gang; Enclosure Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group F G, Class III, NEMA 3/7BCD/9EFG; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#DSD934Customer Part#Campbell Part# CRODSD934
- Feraloy Iron Alloy Pilot Light Control StationPilot Light Control Station; Constructional Feature Explosionproof, Dust-Ignitionproof, Rain Tight, Wet Location; Lamp Type Incandescent; Color Red; Number of Pilot Lights 2; Enclosure Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group F G, Class III, NEMA 3/7BCD/9EFG; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#DSD948 J1Customer Part#Campbell Part# CRODSD948J1
- 3/4 Feraloy Iron Alloy Control Station Back BoxControl Station Back Box; Brand Name FlexStation; Type Dead End; Number Of Gangs 1; Number Of Hubs 1; Hub Size 3/4 Inch; Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group E F G, Class III, Zone 1 and 2 Group IIB, NEMA 3R/7BCD/9EFG/12; Size 3-1/2 Inch W x 3-1/16 Inch D x 5-3/32 Inch H; Mounting Feet; Used On EDS/EFS Series Control Station; Approval UL 1203Detailed Description LessBrandCrouse-HindsMfr. Part#EDS271Customer Part#Campbell Part# CROEDS271
- 3/4 Feraloy Iron Alloy Control Station Back BoxControl Station Back Box; Brand Name FlexStation; Type Dead End; Number Of Gangs 2; Number Of Hubs 1; Hub Size 3/4 Inch; Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group E F G, Class III, Zone 1 and 2 Group IIB, NEMA 3R/7BCD/9EFG/12; Size 7-3/16 Inch W x 3-1/16 Inch D x 5-3/32 Inch H; Mounting Feet; Used On EDS/EFS Series Control Station; Approval UL 1203Detailed Description LessBrandCrouse-HindsMfr. Part#EDS272Customer Part#Campbell Part# CROEDS272
- 120 To 277VAC 20 Ampere Snap Switch Control StationSnap Switch Control Station; Type Feed Through; Constructional Feature Explosionproof, Dust-Ignitionproof, Rain Tight, Wet Location; Voltage Rating 120 to 277 VAC; Current Rating 20 Ampere; Contact Configuration 1 Pole; Operator Type Front Operated; Box Type Single Gang; Hub Size 3/4 Inch; Enclosure Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group E F G, Class III, NEMA 3/7BCD/9EFG; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#EDSC2129Customer Part#Campbell Part# CROEDSC2129
- 3/4 Feraloy Iron Alloy Control Station Back BoxControl Station Back Box; Brand Name FlexStation; Type Feed Through; Number Of Gangs 1; Number Of Hubs 2; Hub Size 3/4 Inch; Material Electrogalvanized and Aluminum Acrylic Painted Feraloy Iron Alloy; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group E F G, Class III, Zone 1 and 2 Group IIB, NEMA 3R/7BCD/9EFG/12; Size 3-1/2 Inch W x 3-1/16 Inch D x 5-3/32 Inch H; Mounting Feet; Used On EDS/EFS Series Control Station; Approval UL 1203Detailed Description LessBrandCrouse-HindsMfr. Part#EDSC271Customer Part#Campbell Part# CROEDSC271
- 1 Inch Copper Free Aluminum Modular Control Station BodyModular Control Station Body; Type Feed Through; Number Of Gangs 2; Construction Tandem; Number Of Hubs 2; Hub Size 1 Inch; Material Natural Finished Copper Free Aluminum; Enclosure Class I Div 1 and 2 Group C D, Class I Div 2 Group B C D, Class II Div 1 Group E F G, Class II Div 2 Group F G, Class III, NEMA 3/7BCD/9EFG; Size 3-1/2 Inch W x 3-5/16 Inch D x 12-3/8 Inch H; Mounting Feet; Used On EDS/EFS Series Control Station; Approval UL 1203, CSA C22.2Detailed Description LessBrandCrouse-HindsMfr. Part#EDSCM32Customer Part#Campbell Part# CROEDSCM32
- 125VAC 20 Ampere Pin/Sleeve Receptacle AssemblyPin and Sleeve Receptacle Assembly; Brand Name ArkGard; Type Feed Through; Voltage Rating 125 VAC; Current Rating 20 Ampere; Hub Size 3/4 Inch; Box Type Two Gang; Cover Type Spring; Mating Plug ENP; Enclosure Class I Div 1 and 2 Group B C D, Class II Div 1 and 2 Group F G, Class III, NEMA 3/7BCD/9FG/12; Approval UL, CSADetailed Description LessBrandCrouse-HindsMfr. Part#ENRC22201Customer Part#Campbell Part# CROENRC22201
- Fire Alarm Station with Pull-Ring Activation - 120V - Wall Mounting, Length (In.) 6 3/8 in, Width (In.) 3 in, Amps AC 60Application: Hazardous areas due to the presence of flammable gases or vapors, combustible dusts, or easily ignitable fibers or flyings. Installation at petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored. Areas where emergency control of fire alarm or signal circuits is required.Detailed Description LessBrandKillarkMfr. Part#XAL-53Customer Part#Campbell Part# KILXAL53